hot sell quality EMC test power source

hot sell quality EMC test power source

  • hot sell quality EMC test power source
  • hot sell quality EMC test power source
  • hot sell quality EMC test power source
  • hot sell quality EMC test power source
Unit Price: T/T paypal  Get Latest Price
Model No.: GF303P
Min. Order: 1
Packaging: standard package
Delivery Time: 7 Days
Place of Origin: beijing china
Brand: GFUVE
Supply Ability: 50/month
Certificate: CE

Product Description

Description

 

 EMC test power source is designed as the special EMC laboratory for the special requirements, and its output by electromagnetic compatible equipment decoupling network can be used as the electromagnetic compatibility of the input of the inspection equipment. It is suitable for power system of electrical measurement, thermal, remote, scheduling and so on need measurement, inspection and high precision standard source power department and the enterprise, especially suitable for metrology institute, electric power academy of sciences as EMC experiment to test equipment to provide standard input. Electromagnetic compatibility test power source is the use of advanced technology and special process design, product anti-interference ability, suitable for attenuation oscillating magnetic field, attenuation oscillation wave, fast transient pulse group, surge and electromagnetic compatibility project immunity test, electromagnetic compatibility test instrument is the necessary equipment. The product has good stability, high degree of automation, use agile and convenient, easy to carry, etc.

 EMC test power source  can be used as the standard source in the electromagnetic compatibility lab, also used to test doing EMC experiment inspected meter`s accuracy. But it can be used with some equipment work together in the electromagnetic compatibility lab: for example surge generator; Group of pulse generator; Frequency drop generator; Electrostatic generator etc.

EMC test power source.jpg

 

Functions and Features

The use of special technology and process, the power supply output anti-interference ability, suitable for various electromagnetic compatible immunity test

Voltage, current and phase, power factor, frequency, etc will set up and take load regulation

It can be set up 2~50 harmonics amplitude and phase, and it can be added to the fundamental wave in every harmonic output

Frequency points phase adjustable (U1U2 and U3 phase)

Voltage and current output range wide, big power, high stability, waveform distortion small

Strong loading ability, and it can take capacity, sensibility, impedance load or composite type load, and the load regulation RG is higher than 0.01%

The 32 bit MPU + DSP + FPGA, powerful agile

Hardware PID, fast response, load change will not cause output fluctuations

Power frequency weekly wave is as high as 50000 points of waveform kneading, signal output without filtering, waveform output precision, harmonic output precision, harmonic distortion small

Range automatic switching; Software calibration, simple operation, stable and reliable

The large screen 320 x 240 liquid crystal display (LCD), English interface, simple operation

Perfect over-current, over-voltage, overheating, short circuit, open circuit, overload protection, automatic fault detection

With RS232 interface, it can connect with PC.

With PC software, it can control standard source output via programmed.

 

Specifications

AC voltage output

Range: 0~120 V; range switch automatically (U1, U2, U3 phase)

Adjust fineness: 0.01% RG

Accuracy: 0.1% RG

Stability: 0.03% RG / 200 s

Distortion degree: <0.1% (not capacitive load)

Output power: 300 VA

Full load regulation rate: 0.01% RG

Full load regulation time: less than 1mS

Long-term stability: ± 60 PPM/year

AC current output

Range: 0~10A; range switch automatically (I1, I2, I3 phase)

Adjust fineness: 0.01% RG

Accuracy: 0.1% RG

Stability: 0.03% RG / 200 s

Distortion degree:< 0.1% (not capacitive load)

Output power: 25 VA

Full load regulation rate: 0.01% RG

Full load regulation time: less than 1 mS

Long-term stability: ± 60 PPM/year

Power output

Accuracy: 0.05% RG

Stability: 0.03% RG / 200 s

Phase angle

Adjusting range: 0 ~ 359.999°

Resolution: 0.001°

Accuracy: 0.1° 

Frequency

Adjusting range: 40 Hz ~ 65 Hz

Resolution: 0.002 Hz

Accuracy: 0.005 Hz

Temperature drift:  ± 0.5 PPM / °C

Long-term stability: ± 4 PPM/year

Power factor

Adjusting range:-1 ~ 0 ~ + 1;

Resolution: 0.0001;

Accuracy: 0.0005.

Harmonic accuracy

Harmonic times: 2~50st

Harmonic phase: 0 ~ 359.99°

Harmonic phase accuracy: < 0.01°

Harmonic set accuracy: 0.1% (relative to the base wave ratings)

With capacitive load capacity

0 ~ 120 V: 1 uF

Power supply:

AC 220 V ± 10%, frequency 50/60 Hz

Environmental conditions

1. Working temperature: 0 °C~ 40 °C;

2. Relative humidity: ≤ 85%;

3. Storage condition:-30 °C ~ 60 °C

Volume and weight

Size: 500 mm x 600 mm x 180 mm;

Weight  about 50 kg.


Email to this supplier
  • *Subject:
  • *Messages:
    Your message must be between 20-3000 characters
Post Sourcing Request >>